  • This delicate digital display temperature controller can set mode or Fahrenheit mode.
  • The ambient and set temperature accuracy is 0.1℃. It is convenient to install and wiring is simple.
  • Wide temperature measurement range from -50℃ to 110℃ and supports high temperature.
  • Can be installed directly or embedded in industrial control equipment panel, convenient and quick.
  • Widely used in the hatching area, equipment, air conditioning system, temperature control and other fields.


Specification:

Input Voltage: DC12V

Temperature Measurement Range: - 50℃~110 ℃

Resolution Ratio: -9.9℃-99.9℃--0.1℃  other temperature intervals--1℃
Measurement Accuracy: 0.1 ℃
Control Accuracy: 0.1 ℃
Return Difference Accuracy: 0.1 ℃
Refresh Rate: 0.5 S
High-temperature: 0-110 ℃
Measurement Input: NTC (10K 0. 5%) waterproof sensor
Output: 20A Relay
Environmental Requirements:
Temperature Requirement: -10 ℃~60 ℃

Humidity Requirement: 20%-85%

Machine Power Consumption: static current ≤ 35MA, pickup current ≤ 65MA

Weight: 33g / 1.2oz (approx.)


Package list:

1 * Temperature Controller


Methods of Use:

After Connecting to the power supply and load (referring to the wiring diagram), you can supply power for the controller, the color red manifest for measuring temperature, the following color blue (or red) as required to set the temperature

In the of manifesting real temperature and please press the button set, the following setting text digital will flash and temperature, after completing the setting, please wait for 3 it will return automatically, at this controller will automatically disconnect Relay according to the preset temperature, the this senor can meet all kinds of large power load, please make sure the line is correct

The Description of Light and Digital Tube Status:

Light: The off means Relay is disconnected, and the normal light on shows that the Relay has closed.

Digital tube: The sign LLL is the open circuit of sensor and the sign means the measuring range, the controller will forcibly disconnect Relay, the sign --- means high- temperature


The Description of Parameters Function:

Please press the button SET five seconds and then it can enter to the main menu of setting, pressing STC(+)and C/F (-) can switch to P0-P8.

About the adjustment of parameters P0-P8, when you need to adjust P0, firstly please press STC (+) and C / F (-) at the same, and the P0figurewill flash, secondly please press STC (+)and C / F (-) to adjust, if done, finally please press STC (+) and C / F (-) to confirm at the same ,P1-P8 which can be set the parameters of each code like P0according to the needs of their own.

The key C/F is a key for switching Fahrenheit or

Press the key C/F once, and it will manifest F(Fahrenheit mode),and then press the key C/F once, it will show C mode), the default mode is C mode),if there is a big temperature error when you use it, maybe it is F mode.

An example for setting:

If you need to Control the refrigeration equipment

1: Please set into C mode in the code P0:

2:In the of manifesting the actual temperature you should press the key SET, and the following digital of setting text will flash, then press C/F (+) and SET (-) to set the stop cooling temperature, after setting please wait for 3 seconds, it will automatically confirm to return.

3:Return difference setting: Firstly please press the key SET for five seconds all the, and it will enter the setting main menu, secondly press STC (+)and C / F (-) to switch into P1, when switching into P1,please press STC (+) and C / f (-)once at the, the P0figure will flash, then please press STC(+)and C / f (-)to set to difference value(return difference means that you should add several degrees to start, for instance, if the it stops when the stop setting temperature is 25 degrees, you should need to set the cooling temperature to 28 degrees, the value in the code P1should be set 3 degrees, so the return difference value is 3 degrees),after finishing that, finally please press STC(+) C/F (-) at the same to confirm.

4:The steps are set up, the data is automatically saved, and the final result is, in the control of refrigeration equipment, higher than28 degrees to start the refrigeration, refrigeration to 25degrees to stop.

If you need to control the heating equipment:

1: Please set into H mode in the code P0.

2:In the of manifesting the actual temperature you should press the key SET, and the following digital of setting text will flash, then press C/F (+) and SET (-) to set the stop heating temperature, after setting please wait for 3 seconds, it will automatically confirm to return.

3:Return difference setting: Firstly please press the key SET for five seconds all the, and it will enter the setting main menu, secondly press STC (+) and C / F (-) to switch into P1,when switching into P1, press STC (+) and C / f (-) once at the, theP1figure will flash, then please press STC (+) and C / f (-) to set to difference value(return difference means that you should add several degrees to start, for instance, if the it stops when the stop setting temperature is 25 degrees, you should need to set the heating temperature to 22 degrees, the value in the codeP1should be set 3 degrees, so the return difference value is 3 degrees),after finishing that, finally please press STC (+) C/F (-) at the same to confirm.

4:When the steps all are set up,the data are automatically saved ,so as controlling the heating equipment, it will start heating system less than 22 degrees, and it will stop heating when the temperature is 25 degrees.

Code

Explain

Setting range

Factory setting

P0

Heating/cooling

H/C

C

P1

Return difference

0.1-30

2.0

P2

Set limit maximum

+ 110

110

P3

Set limits to the minimum

-50

-50

P4

Temperature correction

-15-15

0

P5

Delay start

0-10

0

P6

High temperature alarm

-50~110

OFF

P7

 

CS/FH

cs

F8

Factory Reset

ON-OFF

OFF


Note:
Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.



New Arrival