c1883d343t

Thank you for visiting our page

KYORITSU Ior leakage monitoring logger 40φ leak sensor 8177 set model KEW

[ Brand ] :kyoritsu electric meter

Detail

[ Condition ]

New


Current range: 10.000/100.00/1000.0mA/10.000A/AUTO Connection method: Single-phase 2-wire, Single-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire Measurement calculation items: Earth resistance component leakage current (Ior), leakage Current (Io), Leakage current effective value (Iom), Reference voltage (V), Reference voltage effective value (Vm), Insulation resistance value (R), Frequency (Hz), Phase angle (θ) Other functions: Digital output Functions, print screen, backlight, data hold Number of inputs: 4 channels of current and 1 channel of voltage Introducing the new IOR logger for leakage troubles! Simultaneous measurement and logging of up to 4 systems. Compatible with various wiring methods (single-phase 2-wire, (Single-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire) ・Achieves high-precision Ior measurement that is not affected by harmonics ・Ior logging is possible in 200 milliseconds, the fastest in the industry ・Lightweight and comes with a magnet on the back The main unit can be installed as is / Can be used as a normal leakage current or load current logger Measuring range [Wiring method] Single-phase 2-wire, single-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire [Measurement calculation item] Ground resistance Component leakage current (Ior), leakage current (Io), leakage current effective value (Iom), reference voltage (V), reference voltage effective value (Vm), insulation resistance value (R), frequency (Hz), phase angle ( θ) [Other functions] Digital output function, print screen, backlight, data hold [Number of inputs] 4 channels of current, 1 channel of voltage [Recording interval] 200/400 msec/1/5/15/30 seconds/1/5/15 /30/60/120 minutes *For recording intervals exceeding 200 msec, record the maximum, minimum, average, and instantaneous values ​​during that time. Earth resistance component leakage current (Ior) [Current range] 10.000/100.00/1000.0mA/10.000A/ AUTO [Accuracy] ±0.2%rdg±0.2%f.s. + Error due to clamp sensor amplitude accuracy + phase accuracy *Clamp sensor amplitude accuracy = Accuracy of only the rdg part of sensor accuracy Error due to phase accuracy = Measured value of leakage current Io ±2.0% rdg [Valid input range] 1 to 110% (rms) of each range and 200% (peak) of each range [Display range] 0.15 to 130% of each range (0.15% to 130% (less than 0.15% is displayed as 0, more than 130%) is OL display) Leakage current (Io) *Current range, effective input range, and display range are the same as earth resistance component leakage current (Ior) [Accuracy] ±0.2%rdg±0.2%f.s. + Clamp sensor amplitude accuracy Leakage current effective value (Iom) *Current range, effective input range, and display range are the same as earth resistance component leakage current (Ior) [Accuracy] ±0.2%rdg±0.2%f.s. + Clamp sensor amplitude accuracy [Measurement method] 40.96ksps (24.4μs) , Calculate the effective value every 200 msec without gap Reference voltage (V) [Range] 1000.0V [Accuracy] ±0.2%rdg±0.2%f.s. (sine wave 40~70Hz) [Effective input range] 10~1000Vrms and , 2000Vpeak [Display range] 0.9 to 1100.0Vrms (0 is displayed if less than 0.9V, OL is displayed if it exceeds 1100V) Reference voltage current phase difference (θ) [Display range] 0.0° to ±180.0° (of reference voltage V (Assuming the phase is 0.0°) [Accuracy] Within ±1.0°. Sine wave 40~70Hz, reference voltage 90Vrms or more, input of 10% or more of Io range General specifications [Frequency] 40~70Hz [Display/LCD display update] 160 x 160 dots monochrome LCD / 0.5 seconds [Memory card] SD card (2GB) *Standard included [PC communication] USB Ver2.0 [Compatible standards] IEC61010-1 CAT IV 300V, CATIII 600V Pollution degree 2. IEC61010-2-030, IEC61010-031, IEC61326 [Accuracy guaranteed temperature and humidity range] 23 ± 5 °C relative humidity 45 to 85% (no condensation) [Operating temperature and humidity range] -10 to 50 °C relative humidity 85% or less ( (No condensation) [Storage temperature and humidity range] -20~60°C Relative humidity 85% or less (No condensation) [External power supply] AC100~240V (50/60Hz) 7VAmax [Battery used] AA alkaline batteries (LR6) ×6 (Continuous use time: Approximately 11 hours) [External dimensions/weight] 165 (L) × 115 (W) × 57 (D) mm/Approx. 680 g (including battery) [Accessories] Voltage test cord, AC adapter , ground cord, USB cable, SD card, carrying bag, instruction manual, identification marker, installation manual, 6 AA alkaline batteries (LR6), KEW Windows for KEW 5050 (software) [Set product] 8177 (Ior leak) Sensor 10A type φ40mm)


[ Country of Manufacture ]

If "Made in Japan" is NOT described on whole listing page,
Items are manufactured in other country (China, Vietnam and etc.).


[ Manual & Menu Language ]

We treat Japanese Market Usage Items.
So items have only Japanese Manual & Menu Language.
Please contact us if you would like to know more details.

*Japanese Menu Only : Panasonic Camera
*English Menu available : Nikon, Canon


[ Warranty ]

Japanese Warranty Only.
Buyers need to send item to us in Japan to repair with warranty & own all shipping cost.
If you need to repair item in your country with warranty, please do not order this item.


[ Electronics ]

Japan Usage Item.
Voltage:100V, Plug :Type A, FM Tune:70-90MHz
Please check your country's condition for use.


[ Multiple sizes and colors ]

Before your payment, please contact us about stock of size & color.


International Buyers

[ International Buyers - Please Note ]

- Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
- Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
- These charges are normally collected by the delivering freight (shipping) company or when you pick the item up.
Please do not confuse them for additional shipping charges.

Shipping

[ Shipping Address ]

We ship to only address where be registered on eBay.



[ Combine shipping & Large Quantity ]

Please contact us for combine shipping & large quantity deals before payment.
We do our best for you!!!!!


[ Li-ion Battery ]

Some countries( Germany,France,Italy,Mongolia,SriLanka,Turkey,Nigeria and more.) does not accept lithium battery via EMS, SAL by Post Office.

Please check your country's rule yourself. If we receive order from buyer who located in these countries, we will ask buyer to choose 1 from 3.

1. Ship without Ri-ion Battery removed from item.

2. Change shipping method to Fedex or DHL with additional shipping cost.

3. Cancel