Beschreibung

KnuKonceptz 0 Gauge 3 Way Fuse Block


The BK-2030 inputs accepts two 0 - 4 gauge and output two 0 - 4 gauge and one 4 - 8 gauge power wire without the use of adapters. Oversized allen screws can secure either gauge without any modification or additional parts to complicate the design.

Bassik - simple, clean, easy. This is the foundation of what KnuKonceptz calls Bassik. Easy to install, simple to connect and cost effective. This block is shown in satin nickel finish with polished nickel plated allen screws and smoke black base. The BK-2030 includes three fuses to configure this block for power applications.

PLEASE NOTE FUSE SIZE IN eBay ORDER NOTES
Fuses Sizes - 40 / 60 / 80 / 100 / 120 /150 / 200 / 240

We will ship 200A / 40A / 80A outputs if no fuses are noted, comes as 2- 100A 3- 40A fuses!

Spezifikationen 

KnuKonceptz BK-2030 3 Way Fuse Block
Dimensions / Maße 92mm(L) x 79mm(W) x 32mm(H) 
Input Gauge / Eingang Two 0 - 4 Gauge  (20-55mm^2)
Output Gauge / Ausgang Two 0 - 4 Gauge  (20-55mm^2) + One 4- 8 Gauge x 2  (8-20mm^2)
Fuse Type / Sicherung Mini-ANL inbegriffen 
Finish / Überzug Nickel Silver / Nickel Silber

Zusätzliche Information

Flexibility - Dual Cable Inputs


The BK-2030 Fuse Block has dual cable inputs, only one is required to power all three outputs. With the second cable port you can:

  • Daisy chain additional blocks for additional outputs in larger systems
  • Connect to a rear mounted battery, linking it to the rest of your system
  • Add a capacitor into the system
  • Using both inputs from a battery source will reduce voltage loss
  • IF Installing a combined fuse rating over 350A (total sum of fuses installed), connecting both inputs to a battery source is advised.

High Current Capacity - Fuses in Parallel


  • Using multiple smaller fuses in parallel reduces voltage loss across the connection
  • This is from the increased surface area of a multiple fuses versus a single fuse
  • Less voltage loss means more power to your system
  • Achieve higher amperage capacity in a compact space. Multiple smaller fuses can achieve higher loads than a single fuse due to thermal capacity
  • When ordering, you will receive two fuses per 0 gauge circuit and a single fuse for the 4 gauge output. The 0 Gauge Fuse will total the fuse rating you selected. Ex: ordering 240A fuse, you will receive 120Ax2 per 0 Gauge output (240A total)

No Adapters Needed - Oversized Hardware


  • Internal gauge adapters add unnecessary contact points
  • Extra contact points can increase resistance, lowering your voltage.
  • By using larger diameter set screws, our block can hold a large or small gauge wire without the need for an adapter

Häufig gestellte Fragen

Q: How do I determine what size fuses I need for this fuse block?
A: Each output of a fuse distribution block normally is connected to a single amplifier. Each amplifier will have either a fuse on board or the manufacture will state within the manual's installation guide or spec sheet what the max fuse rating or current draw of the amplifier is. If your amp has three 30A fuses on boards, you want a 100A fuse for that particular output of this block (90A is not an option we offer). If the second amp has a single 40A fuse, then a 40A fuse goes into that output of the block and thus a 100A and 40A would be required.
Q: The 0 Gauge output on the BK-2030 uses two fuses, why?
A: To achieve higher load capacity, the fused 0 gauge output each use two Mini-ANL fuses. When ordering your fuse block, all fused 0 gauge outputs will include two fuses, half the size of the load requested. For example, if you order the BK-2030 with 240A fuses on the 0 gauge output, you will receive 120Ax2 per output.
Q: This block has two inputs, do I need to use both?
A: The BK-2030 has two input ports, only one input is required to power both fused outputs. The second port is optional and can be used to connect additional rear mounted batteries, a capacitor, or to daisy chain additional blocks together. Having the second port makes this fuse block more flexible to the installer than a single port block. IF Installing a combined fuse rating over 350A (total sum of fuses installed), connecting both inputs to a battery source is advised.
Q: Can I use this block as a ground block?
A: Yes, KnuKonceptz offers ground links to turn this block into a 5 Way Ground Block. These Mini-ANL buss bars replace the fuse and allow the BK-2030 to be used from a common grounding point.