Automatic Water Pump Controller Switch Tank Liquid Level Detection Sensor wires
Description
Specification |
|
Type: | DF-96DUpdatedversion |
Working voltage: | AC220V/50HZ |
Max Current: | 20A |
Installation: | DinRailMount |
Power consumption | ≤2W |
transmission signal: | 500M |
Size: | 126*88*51mm |
- Single-control UP pool (water storage) installation instructions shown in figure 1
- A(red)—Upper water level control point. When water level gets to A point,
- the probe touch water and controller can stop the pump by auto.
- B(blue)—Lower water level control point. When water level gets off B point,
- the probe out of reach water and controller can start the pump by auto.
- C(black)—Should be placed in bottom of pool as the common line.
- D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water)installation instructions shown in figure 2.
- E—Upper water level control point. When water level gets to E point,
- the probe touch water and controller can start the pump by auto.
- D—Lower water level control point. As liquid level gets off D point,
- the probe out of reach water and controller can stop the pump by auto.
- C—Should be placed in bottom of pool as the common line.
A&B—disconnected
- Lack of water protection installation instructions shown in figure 3.
- C&D—Lower water level control points. When water level gets off this point,
- C or D probe out of reach water and controller can stop the pump by auto.
E&C—short-connected;
A&B—disconnected
- Joint control UP and DOWN pool installation instructions shown in figure 4.
- A—Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the pump by auto.
- B—Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C—Should be placed in bottom of UP and DOWN pools as the common line.
- D—Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.
- E—Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Used to solve problem:
- On power but no work
- Check the red indicator is on or not. If not, make the connection is good enough;
- When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.
- Whether the probe is placed too high or low so that water level can reach or out of reach it;
- The connection of upper &lower line or probe is dislocation by error or short connected;
- To check the probe whether it is rust or not or the connection is good enough.
- C- Check the common line whether it is placed in the lowermost bottom of pool.
Package include:
- 1pcsAutomatic Water Level Controller Switch
- 3pcs 200CM Sensor