Automatic Water Pump Controller Switch Tank Liquid Level Detection Sensor wires


Description

Specification

Type:

DF-96DUpdatedversion

Working voltage:

AC220V/50HZ

Max Current:

20A

Installation:

DinRailMount

Power consumption

≤2W

transmission signal:

500M

Size:

126*88*51mm

  • Single-control UP pool (water storage) installation instructions shown in figure 1
  • A(red)—Upper water level control point. When water level gets to A point,
  • the probe touch water and controller can stop the pump by auto.
  • B(blue)—Lower water level control point. When water level gets off B point,
  • the probe out of reach water and controller can start the pump by auto.
  • C(black)—Should be placed in bottom of pool as the common line.
  • D(green) and E(yellow)are connected with C (black).
  • Single-control DOWN pool(drain water)installation instructions shown in figure 2.
  • E—Upper water level control point. When water level gets to E point,
  • the probe touch water and controller can start the pump by auto.
  • D—Lower water level control point. As liquid level gets off D point,
  • the probe out of reach water and controller can stop the pump by auto.
  • C—Should be placed in bottom of pool as the common line.

A&B—disconnected

  • Lack of water protection installation instructions shown in figure 3.
  • C&D—Lower water level control points. When water level gets off this point,
  • C or D probe out of reach water and controller can stop the pump by auto.

E&C—short-connected;

A&B—disconnected

  • Joint control UP and DOWN pool installation instructions shown in figure 4.
  • A—Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the pump by auto.
  • B—Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
  • C—Should be placed in bottom of UP and DOWN pools as the common line.
  • D—Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.
  • E—Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected

Used to solve problem:

  • On power but no work
  • Check the red indicator is on or not. If not, make the connection is good enough;
  • When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.
  • Whether the probe is placed too high or low so that water level can reach or out of reach it;
  • The connection of upper &lower line or probe is dislocation by error or short connected;
  • To check the probe whether it is rust or not or the connection is good enough.
  • C- Check the common line whether it is placed in the lowermost bottom of pool.

Package include:

  • 1pcsAutomatic Water Level Controller Switch
  • 3pcs  200CM Sensor