DC12V Voltage Detection Module Relay Charging Discharging Detection Module 99.9V

Product View

Detail

Features.
1.Detecting voltage range: 0-99.9V, minimum 0.1V adjustable.
2. Charge protection, discharge protection
3. Over-voltage protection, under-voltage protection
4. Fixed-point pulse, stable performance
5. Charge and discharge control, stable performance.
Product Parameter
Voltage: DC12V
Relay contact maximum current: 12A
Detection voltage range: 0-99.9V
Parameter setting instructions
Turn on the power to display the voltage into the standby state, first set two basic parameters, the lower limit voltage V1 and the upper limit voltage V2
1. Press the setup key once to display "F1" flashing.
2. Press the setup key for the second time to display the default V1 value "XX.X" blinking. Press the "plus" button or "minus" control key to adjust the lower limit parameter V1.
3. Press the Setup key for the third time to display the default V2 value "XX.X" blinking, press the "plus" key or "minus" key to adjust the upper limit parameter V2 (at this time, if the V1 participation parameter is greater than V2, it will be displayed). X" blinks, press the "plus" button or "minus" button to adjust the upper limit parameter V2 (if V1 participation parameter is greater than V2, it will be displayed. "ERR" error message, need to change the parameter, be sure to keep V1 less than V2 as normal)
4. Press the Setup button for the fourth time, the parameter will be kept permanently and quit.
5. In standby mode, press the "minus" button for 3 seconds to turn off the display, and press it again for 3 seconds to turn on the display. Designed to reduce power consumption
Function Description
1.F-1 Charging monitoring: when the measured voltage is lower than the voltage V1, the relay will absorb, and the voltage is higher than V2, the relay will disconnect.
2.F-2: Discharge monitoring: when the measured voltage is higher than the voltage V2 relay is activated and the voltage is lower than V1 relay is disconnected.
3. F-3: Out-of-range engagement: when the measured voltage is introduced between V1 and V2, the relay is disconnected.
4. F-4: Intra-range engagement: when the measured voltage is introduced between V1 and V2, the relay is engaged and the other status relays are disengaged.
5. F-5: Fixed-point monitoring: Relay is activated when the measured voltage is higher than V1 and deactivated when it is lower than V1.
6.F-6: Fixed-point self-locking monitoring: when the measured voltage is higher than V1 relay is engaged and remains engaged until manual disconnection.
7.F-7: Fixed-point pulse monitoring: when the measured voltage is equal to V1 every time (floating up and down by 0.1V), the relay outputs an actuating signal.
8.F-8: New function, voltage error correction, range ±5.0V.

Setting method added
In F-1 set up, set up after the other functions of the parameters are used in F-1 set parameters. After pressing the setup key with blinking F-1, then press + or - to adjust the function number, and then press the setup key again after adjusting to a certain function number, then it is OK. After pressing the setup button, the F-1 blinks, then press + or - to adjust the function number, and then press the setup button again after adjusting to a certain function number, then it is OK.
 
Shipping List.
Relay module 1

We only accept your Ebay Address, Please Make sure it's 100% right.

The items you ordered will be shipped out in 3 business day by Hong Kong Air Mail when your payment is clear.

We maintain high standards of excellence and strive for 100% customer satisfaction!

Feedback is very important to us. We request that you contact us immediately BEFORE you give us neutralor or negative feedback, so that we can satisfactorily address your concerns.

Copyright © 2017 DataCaciques

Product View

Detail

Features.
1.Detecting voltage range: 0-99.9V, minimum 0.1V adjustable.
2. Charge protection, discharge protection
3. Over-voltage protection, under-voltage protection
4. Fixed-point pulse, stable performance
5. Charge and discharge control, stable performance.
Product Parameter
Voltage: DC12V
Relay contact maximum current: 12A
Detection voltage range: 0-99.9V
Parameter setting instructions
Turn on the power to display the voltage into the standby state, first set two basic parameters, the lower limit voltage V1 and the upper limit voltage V2
1. Press the setup key once to display "F1" flashing.
2. Press the setup key for the second time to display the default V1 value "XX.X" blinking. Press the "plus" button or "minus" control key to adjust the lower limit parameter V1.
3. Press the Setup key for the third time to display the default V2 value "XX.X" blinking, press the "plus" key or "minus" key to adjust the upper limit parameter V2 (at this time, if the V1 participation parameter is greater than V2, it will be displayed). X" blinks, press the "plus" button or "minus" button to adjust the upper limit parameter V2 (if V1 participation parameter is greater than V2, it will be displayed. "ERR" error message, need to change the parameter, be sure to keep V1 less than V2 as normal)
4. Press the Setup button for the fourth time, the parameter will be kept permanently and quit.
5. In standby mode, press the "minus" button for 3 seconds to turn off the display, and press it again for 3 seconds to turn on the display. Designed to reduce power consumption
Function Description
1.F-1 Charging monitoring: when the measured voltage is lower than the voltage V1, the relay will absorb, and the voltage is higher than V2, the relay will disconnect.
2.F-2: Discharge monitoring: when the measured voltage is higher than the voltage V2 relay is activated and the voltage is lower than V1 relay is disconnected.
3. F-3: Out-of-range engagement: when the measured voltage is introduced between V1 and V2, the relay is disconnected.
4. F-4: Intra-range engagement: when the measured voltage is introduced between V1 and V2, the relay is engaged and the other status relays are disengaged.
5. F-5: Fixed-point monitoring: Relay is activated when the measured voltage is higher than V1 and deactivated when it is lower than V1.
6.F-6: Fixed-point self-locking monitoring: when the measured voltage is higher than V1 relay is engaged and remains engaged until manual disconnection.
7.F-7: Fixed-point pulse monitoring: when the measured voltage is equal to V1 every time (floating up and down by 0.1V), the relay outputs an actuating signal.
8.F-8: New function, voltage error correction, range ±5.0V.

Setting method added
In F-1 set up, set up after the other functions of the parameters are used in F-1 set parameters. After pressing the setup key with blinking F-1, then press + or - to adjust the function number, and then press the setup key again after adjusting to a certain function number, then it is OK. After pressing the setup button, the F-1 blinks, then press + or - to adjust the function number, and then press the setup button again after adjusting to a certain function number, then it is OK.
 
Shipping List.
Relay module 1

1.We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.

2.Orders will be processed instantly and dispatched within 1-2 business days except hoilday, so we do NOT accept any email/message note after you place orders.

3.Usually, the package will be delivered in about 30 days, some remote areas may wait longer.

1.We accept PayPal payment, and must be received within 5 days from the date of purchase.

2. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.

3.Buyers are responsible for import duties,custom fees and taxes, if any, please check your country.

1.We believe our items are so outstanding. We are convinced you will be happy with your Purchase.

2. If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund or resend the item to you after the returned item arrived at our warehouse.

3. Please include your eBay ID and item number with any email requests.

1.We greatly appreciate your POSITIVE feedback. Please do NOT leave negative feedback or open a case without asking for help.

2.Please DON'T leave negative / neutral feedback or open case if you haven't received item in 30 days, International shipping is uncontrollable, sometimes the package may be delayed, If you have't receive item in time, Please remember to contact us to resolve.

1. If you have any questions, please feel free to email our service specialists.

2.Just contact us using the " Ask the seller a question" link on eBay.

3.Our aim is to provide Top Level Customer Service, normally so we will try our best to solve any problem.

DataCaciques