MPPT 60AMP Solar Charge Controller For 12V 24V 36V 48V DC Battery Regulator
60A MPPT Solar Panel Regulator Charge Controller DC12/24/36/48V Auto Max PV 190V
 

FEATURE:

  • Charging 3-stage: constant current(MPPT), constant voltage(Absorption Voltage), floating charge
  • Selectable battery type Vented / Sealed / Gel / NiCd / Lithium battery (default is Sealed) (defined voltage for other battery by user)
  • Soft start time ≤1S, Dynamic response and recovery time 100us
  • Max efficiency ≥98.1%, PV utilization ≥99%
  • In order to reduce the cost of electricity caused by high current, PV and battery each have two terminals
  • MULTIPLE ELECTRONIC PROTECTIONS
  • Short-circuting
  • Reverse-current
  • Overcharging
  • Overload
  • Over-discharging
  • Reverse polarity protection

Notes: The output terminal is for lamp only( 12V system less 60W, 24V/36V/48V system less 100W ),and it will be burnt if connecting to other loads. The output for battery is no polarity reverse protection.

Remarks:
1. The maximum PV input voltage (Voc): DC160V (The controller can not work with this long duration voltage, which will interrupt the controller. Refer to the input voltage of PV).
2. The output port is only for lamps (12V system less 60W, 24V/36V/48V system less 100W) and will be burned if connected to other loads. The battery output is not reverse polarity protection.
3. Always connect the battery first!!! Make sure the battery voltage is sufficient for the controller to recognize the correct system voltage. The order of dismantling contradicts the order of wiring.
4. Do not connect any inverter/wind/generator or charger to the controller, please connect the inverter to the battery side.
5. Ensures the solar input voltage exceeds 3V or more than the battery voltage and the total input power exceeds the max. , the charging current is almost zero when the controller has trickle charge.

Parameter

Model Name

MPPT-60A

Charging mode

MPPT Maximum power point tracking automatically

Charging

3-stage:constant current(MPPT), constant voltage(Absorption Voltage), floating charge

System type

DC12V/24V/36V/48V Recognition automatically

System voltage automatic recognition

12V system (DC9V-DC15V)

24V system (DC18V-DC29V)

36V system (DC30V-DC39V)

48V system (DC40V~DC60V)

Soft start time

≤1S

Dynamic response and recovery time

≥98.1%  (Voc is 1.5 or 2 times than battery, then it’s best efficiency)

PV utilization

≥99%

Input specification

Voc from PV( Make sure the Voc of PVmeeting the requirement as right. Voc is 1.5 or 2 times than battery, then it’s best efficiency. )

12V system (DC20V~DC80V)

24V system (DC37V~DC105V)

36V system (DC50V~DC160V)

48V system (DC72V~DC160V)

The maximum PV input voltage (Voc)

DC190V(The controller can’t work at this voltage of long duration that will break controller. Please refer to Input voltage from PV.)

The maximum PV input power(The total power rated of PV can’t be over this watt that will break the controller.)

12V system  (720W)

24V system (1440W)

36V system (2100W)

48V system (2800W)

Output specification

Selectable battery type(default is Sealed)

Vented/ Sealed / Gel / NiCd / Lithium battery(defined voltage for other battery by user)

Absorption Charging Voltage

Refer to Batteries charging reference

Floating Charging Voltage

Refer to Batteries charging reference

Overcharging protection voltage

12V system (15V)

24V system (30V)

36V system (45V)

48V system (60V)

Rated output current

60A

Temperature Coefficient

±0.02%/ centi-degree

Automatic temperature compensation

14.2V-(Max temperature-25 centi-degree)*0.3

Output voltage ripple-peak

100mV

Output voltage accurac

≤±1%

Input Anti-intrusion protection

yes

Temperature Protection

75°C

Temperature increased protection

Output power will reduce when it’s more 70 °C

Output power will be normal when it’s less 55 °C

Fan-on temperature

>40 °C

Fan-off temperature

<35 °C

Acoustic noise

≤40dB

Cooling way

Forced air cooling

Components

Imported materials, Accord  to EU standards, Industrial grade range.

Environmental requirements

Meet 2002/95/EC; No cadmium, hydrides and fluorides

Security Level

Accord to CE, PSE, FCC, EMC, EN60950

Electromagnetic Compatibility

Accord to EN61000, EN55022, EN55024

Enclosure

IP21

Net weight(Kg)

1.1

Gross weight(Kg)

1.2

 
 
 
 

TIPs

  1. Always connect battery first!!! Make sure enough batteries’ voltage let controller recognize the right system voltage. The disassembly sequence is contrary to the wiring order. NEVER connect the solar panel array to the controller without a battery
  2. DO NOT connect any Inverter/ wind/ Alternator or Charger into the charge controller! connect the Inverter directly to the battery.
  3. Ensures solar input voltage higher 3V or more than batteries’ voltage and total input power in the range. if input power is too low for max input power, it may be appears to have been discontinued., the charging current almost be zero when controller is floating charge.
  4. Parameter Setting RulesFloating voltage > Low voltage reconnect > Low voltage discharge.
  5. The solar controller will stop output when the battery under 10.7V. The LCD will be blank when the battery under 8V and it will re-output when the battery up to the 12.6V (adjustable).
  6. Install the Charger controller to the battery as close as possible. Tighten the wire, Carefully read battery manuals before operation.
  7. When controller makes buzzing sound because of It's working hard to dissipate heat for your controller. Rest your heart, it will be stop when temperature return to normal.
  8. Remove all the debris around the controller ( leaving a space of approx. 5.91in ).Make sure all connections going into and from the controller are tight. Do NOT let the positive (+) and negative (-) terminals of the battery touch each other.
 
PushAuction