Arc Fault protective RCBO

Product Description

Overview

GDDF3-40 incorpaorating MCB ,RCD and arc fault detection module, provides protection against short circuit, overload, leakage current and arc fault.Zero-sequence transformer of RCD detects leakage current, and arc fault module detects arc fault, which enable the product effectively disconnect the protected circuit in case of either leakage current fault or arc fault.



Application

GDDF3-40,applicable to AC circuit with rated current up to 40A, provides protection against arc fault, overload, short circuit and leakage current fault happened to branch circuits in lighting distribution and power distribution system.

The arc fault detection module of GDDF3-40 can effectively detect and identify arc faults in its protected circuit with desabled insulation layer due to aging, damaging or high humidity. The product trips and disconnects the circuit upon detection of arc faults.


Technical parameters

Rated voltage(Ue) AC230V
Rated frequency 50HZ±2%
Rated insulation voltage(Ui) 400V
Rated impulse withstand voltage(Uimp) 4KV
Rated current(In) 6-40A
Number of poles 1P+N(N pole disconnectable)
Magnetic tripping type B-type C-type
Rated service short circuit capacity(lcs) 6KA
Rated short circuit capacity(Icn) 6KA
Insulation material class Ⅲa
Grid distance(mm) 40mm
Rated sensitivity 30mA type A AC



Normal operating conditions

Ambient temperature is 5℃ or + 40℃,the average daily highest temperature is +35℃.
Relative humidity:Maximum value is 50% when the temperature is 40℃ and 90% when the temperature is 20℃.



Indicating light function scheme

Instruction:When installing this product,disconnect the upper stream power supply, and then connect the LINE and LOAD as per following steps:

1.Turn on upper stream power supply, switch on the GDDF3-40,the illuminated push button flashes with green light at time interval 0.6s and the product starts normal service

2.Switch on GDDF3-40, connect load, press test button, the product trips, the green light turns off and the illuminated push button flashes once with yellow light fand goes off,which means product is at normal service.

3.During normal operation of a load, if the GDDF3-40 trips both green and yellow indicating light turns off, then first disconnect load and then switch the product handle to ON position.If the yellow indicating light flashes for 5-6 times and then turns off, last trip must have been caused by arc fault. If the yellow indicating light does not flash, last trip must have been resulted from overload or short circuit.trips and the illuminated push button pops up, then first disconnect load, reset illuminated push button and switch the product handle to ON position. If the yellow light flashes for 5-6 times and then turns off, last trip must have been caused by arc fault. If illuminated push button does not pop up, last trip must have been resulted from overload or short circuit.

4.4.Confirmation about arc fault happened to the down stream circuit.After sequence 3 is performed,switch on ADDF3-40,connect again the load to the product and try to operate the load.If the yellow light flashes once, the product trips and circuit gets disconnected, then arc fault must have occurred. Professional electrician is requested to investigate and correct the protected circuit.

5.5.Contact the supplier or manufacturer for any abnormal service.



Installation

*Inspection should be carried out before installation to ensure that GDDF3-40 is intact and flexible, the mark is in conformity with the usage requirement.

*A protective metal panel with earth connection or a panel made of insulated material shall be mounted as prevention against electric shock if an GDDF3-40 is installed separatedly other than being installed in a distribution box.

*Any calibration on GDDF3-40 by user is prohibited.


More Type of breakers for you consider

AC MCB 1-4 Pole 6-125A 6kA for AC Type 
DPN MCB 1P+N 6-40A Curve B/C for AC Type
DC MCB 1-4 Pole 6-125A 6kA for DC Type 
DC MCCB 2 Pole 125-320A 8kV for DC Type
RCD RCCB 2P Type AC Earth Leakage Breaker 2P 25-100A 30/100/300mA AC Type
RCD RCCB 4P Type AC Earth Leakage Breaker 4P 25-100A 30/100/300mA AC Type
RCD RCCB 2/4P Type A Earth Leakage Breaker 2/4P 40/63A 100/300mA A Type
RCD RCCB 2/4P Type AC-S Earth Leakage Breaker 2/4P 40/63A 100/300mA AC-S Type
RCD RCCB 2/4P Type B Earth Leakage Breaker 2/4P 40/63A 100/300mA B Type
RCBO 2P Type AC Over Current&Leakage Protection 2P 10-40A 30/100/300mA AC Type
RCBO 2P Type A Over Current&Leakage Protection 2P 10-40A 30/100/300mA A Type
Isolator Breaker Isolator Breaker 1-4 Pole 63-125A
AFDD Arc Fault protective Fire Prevention Monitoring 40A 30mA
MCB Recloser Self-Reclosing Device with MCB 1-4 Pole 16-63A
RCCB Recloser Self-Reclosing Device with RCCB 2/4 Pole 40/63A 30/100/300mA


We only accept payment via Paypal at present.  If you want to pay by other method, please contact me.

We will process your order within 1 business day upon payment except holidays and weekends. Once I update tracking number, orders can not be canceled. 


Economy shipping:

all economy shipping parcels dnot comwith tracking information or only provide tracking information when parcels are in China. If you haven't recieved your parcels after wait a long time, please contact your local post office to check your parcel by providing your recipient's name and mobile phone number. 


Standard shipping:

standard shipping parcels provide whole tracking information. Suggested!


Expedited shipping:

If you need expedited shipping service, please contact me. 

Please read the item description and check the pictures carefully before making orders. Return or refund is available if:
 
1. The item was damaged in transit.
2. Product quality problem.
 

When you submit a return or refund application, please 

1. Provide a detailed problem description and photos so that we can deal with it as soon as possible. 

2. Please obey my requirments about packing of return goods. After warehouse staff recieve and check your parcel is ok, then I will refund you.

Please read the item description and check the pictures carefully before making orders. Return or refund is available if:
 
1. The item was damaged in transit.
2. Product quality problem.
 

When you submit a return or refund application, please 

1. Provide a detailed problem description and photos so that we can deal with it as soon as possible. 

2. Please obey my requirments about packing of return goods. After warehouse staff recieve and check your parcel is ok, then I will refund you.


On Mar 24, 2024 at 08:20:33 PDT, seller added the following information:

DataCaciques