CiTiceL BW Oxygen Sensor SR-X2V 40XV AAY80-390R / AAY80-390 for Coal Mine Oxygen
Product Name: Oxygen City sensor module Oxygen sensor 4OXV Scope of application: Oxygen sensors are widely used in coal mines, iron and steel, petrochemical industry, medical treatment and so on Typical applications: Oxygen alarm, atmosphere analyzer After the analog signal output by the oxygen electrochemical sensor is amplified by the module, it is sent into the ADC acquisition port of STM32 single-chip microcomputer. After the filtration operation inside the STM32 single-chip microcomputer, the oxygen concentration in the air is calculated and then output from the serial port. The module is compatible with 4OXV, Me2-O2, AAY80-390R and other electrochemical probes. Module uses high precision rail-to-rail amplifier AD86XX amplifier circuit, integrated ARM Cortex M0 32-bit CPU, 12-bit ADC sampling, serial port output oxygen concentration, can be calibrated through the serial port output value, baud rate 115200. Electrochemical gas sensor is based on the principle of electrochemistry, using the measured gas on the sensor working electrode and electrode corresponding REDOX reaction and release charge, through the external circuit to form a current, current size is proportional to the concentration of gas, so as to achieve the quantitative measurement of the target gas. Applicable fields: It can be used in automobile, home, laboratory, coal mine, steel, petrochemical, medical and other measuring environments. Parameters Working principle: electrochemistry Measuring range: 1-25% Maximum overload: 30% Output signal: 0.10±0.02mA in the air Response time (T90): <15S Zero current (bias): <0.6% Linear: It can be considered linear in many cases Recommended load resistance: 100 ohms Shell material: ABS Weight: <16 g Azimuth sensitivity: <0.2% Operating temperature range: -20°C to +50°C Recommended storage temperature: 0℃-20℃ Thermal transient (temperature plunge +22°C to -20°C): <23.5% Working pressure range: ±20% of atmosphere Pressure coefficient: <0.02%/Mbar Pressure dynamics (60 cm water column step change): <200% signal change Continuous relative humidity range (at 0℃ to 20℃): 5~95%RH non-condensing Short-term relative humidity range (at 0℃ to 20℃): 0~99%RH non-condensing Long-term output drift: <2%/month, the entire working life is usually <5% Expected working life: 24 months in the air Storage life: 6 months in original packaging Package Include: 1pcs x CiTiceL BW Oxygen Sensor SR-X2V 40XV |