NEW Omron E5CC-RX2DSM-800 24VAC/DC Temperature Controller Complete Range of I/O
Product Description
Omron has been an active innovator in temperature control since introducing its first temperature controller in 1967. Now temperature control has taken a giant leap forward with Omron's next generation of controllers - the E5[]C, which set new global standards in the crucial areas of precision, user friendliness and control performance. The E5[]C series will save you time and effort in set-up and operation, while enabling faster and more accurate monitoring/control of your process. The high-visibility display of the new series is also extremely easy to read and virtually eliminates any possibility for human error.
Availability: Customize Usually Ships within 2-4days
High-contrast, white LCD display visible from large distances and from any angle
Easy to set up, and operate intuitively via CX-Thermo without power supply
50 ms sampling period for fast and precise regulation
Functions for diagnosis for secure operations *
Useful timer and logic operation functions eliminating the need of a PLC
Specification:
Power supply voltage
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
Models with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or 1.6 W max. at 24 VDC All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Sensor input
Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance
Current input: 150 O max., Voltage input: 1 MO min. (Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method
ON/OFF control or 2-PID control (with auto-tuning)
Control output
Relay output
E5CC-800: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA E5CC-U-800: SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
4 to 20 mA DC/0 to 20 mA DC, load: 500 O max., resolution: approx. 10,000
Auxiliary output
Number of outputs
2
Output specifications
SPST-NO relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Event input
Number of inputs
2 or 4 (depends on model)
External contact input specifications
Contact input: ON: 1 kO max., OFF: 100 kO min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Setting method
Digital setting using front panel keys
Indication method
11-segment digital display and individual indicators Character height: PV: 15.2 mm, SV: 7.1 mm
Multi SP
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.
Other functions
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, PV input shift, run/stop, protection functions, temperature status display, moving average of input value
Ambient operating temperature
-10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C (with no condensation or icing)
Ambient operating humidity
25% to 85%
Storage temperature
-25 to 65°C (with no condensation or icing)
Altitude
2,000 m max.
Recommended fuse
T2A, 250 VAC, time lag, low shut-off capacity
Installation environment
Installation Category II, Pollution Class 2 (IEC 61010-1 compliant)
Indication accuracy (at the ambient temperature of 23°C)
E5CC-800 Thermocouple: (?.3% of PV or ?°C, whichever is greater) ? digit max. *1 Platinum resistance thermometer: (?.2% of PV or ?.8°C, whichever is greater) ? digit Analog input: ?.2% FS ? digit max. CT input: ?% FS ? digit max. E5CC-U-800 Thermocouple: (?% of PV or ?°C, whichever is greater) ? digit max. *1 Platinum resistance thermometer: (?.2% of PV or ?.8°C, whichever is greater) ? digit Analog input: ?.2% FS ? digit max.
Simple transfer output accuracy
?.3% FS max.*2
Influence of temperature *3
Thermocouple input (R, S, B, W, PL II): (?% of PV or ?0°C, whichever is greater) ? digit max. Other thermocouple input: (?% of PV or ?°C, whichever is greater) ? digit max. *4 Platinum resistance thermometer: (?% of PV or ?°C, whichever is greater) ? digit max. Analog input: ?%FS ? digit max. CT input: ?%FS ? digit max.
Influence of voltage *3
Input sampling period
50 ms
Hysteresis
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Proportional band (P)
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I)
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D)
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Proportional band (P) for cooling
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) for cooling
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D) for cooling
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Control period
0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)
Manual reset value
0.0 to 100.0% (in units of 0.1%)
Alarm setting range
-1999 to 9999 (decimal point position depends on input type)