Product Description

The No.1000 is a precise mechanical watches test instrument, it is used for multi-testing
 
by watch manufacturers and watch technician.
 
Feature

 
1. The frequency diagram of the watch can be displayed in the LCD screen.
 
2. According to different watches, the instrument will automatically adjust optimal signal level during testing.
 
3. The instrument will automatically calculate the rate, amplitude, beat error, and display them by data in real time.
 
4. For the conventional beat, the instrument can automatically response; for the special beat, can manually select.
 
The sampling period can selected by 2 seconds, 4 seconds, 6 seconds, 8 seconds, 10 seconds, 20 seconds, 30 seconds,
 
60 seconds, and the average of corresponding period will be regard as the precise value of the watch.
 
5. Six kinds of testing position can be adjusted, and the simulation sound can be play in the speaker or mute.
 
 Parameters

 
1. Beat Numbers (Frequency Numbers):
 
The following beat numbers are selected by automatic selection mode:
 
12000,14400, 18000, 19800, 21600, 25200, 28800, 36000, 43200.
 
(If the tested beat is not in automatically selection, the instrument will display the closest beat number,
 
but the test result is not correct. At this time, use the manual mode to select the relative beat.)
 
Manual selection can selected out the beat number that Automatic select can not identify and rare beat number.
 
The following beat are selected by Manual selection mode:
 
3600,6000, 7200, 7380, 7440, 7800, 9000, 9100, 10800,11880,12000,12342,12480,12600,
 
13320,13440,13500,14000,14040,14160,14200,14280,14400,14520,14580,14760,14850,15000,
 
15360,15600,16200,16320,16800,17196,17258,17280,17786,17897,18000,18049,18514,19332,
 
19440,19800,20160,20222,20944,21000,21031,21306,21600,25200,28800,32400,36000,43200.
 
2.Lift Angle:
 
The lift angle is 52° for many common movements
 
therefore the lift angle value of instrument for factory is set to 52°. This value
 
is required to calculate the amplitude and must be selected according to
 
the watch movement. The lift angle can be set to between 30°and 70°.
 
3.Period:
 
The measuring period selectable 2s、4s、8s、10s、20s、30s、60s
 
Use to recalculate the average values of the test result.
Common Faults & Handling 
 
1. After insert the socket, the screen is dark. Check the power pilot LED is bright or not.
 
2. The instrument can enter testing state with the sound of “Di", but after placed the watch on the sensor,
 
the instrument do not work. Check the second hand whether rotation (and amplitude must be more than 100 °),
 
the crown of watch (leading) is against at the sheet metal of sensor.
 
3. Signal LED is bright, but the lines is scattered or occur many lines. Maybe the beat is mistake,
 
adjusted the right beat (frequency) by manual selection.
 
Package Include

 
1pc Mechanical Watches Tester

Copyright©2017 DataCaciques

Details
 
LCD Screen AC 100V-240V Watch Tester
 

Product Description

The No.1000 is a precise mechanical watches test instrument, it is used for multi-testing
 
by watch manufacturers and watch technician.
 
Feature

 
1. The frequency diagram of the watch can be displayed in the LCD screen.
 
2. According to different watches, the instrument will automatically adjust optimal signal level during testing.
 
3. The instrument will automatically calculate the rate, amplitude, beat error, and display them by data in real time.
 
4. For the conventional beat, the instrument can automatically response; for the special beat, can manually select.
 
The sampling period can selected by 2 seconds, 4 seconds, 6 seconds, 8 seconds, 10 seconds, 20 seconds, 30 seconds,
 
60 seconds, and the average of corresponding period will be regard as the precise value of the watch.
 
5. Six kinds of testing position can be adjusted, and the simulation sound can be play in the speaker or mute.
 
 Parameters

 
1. Beat Numbers (Frequency Numbers):
 
The following beat numbers are selected by automatic selection mode:
 
12000,14400, 18000, 19800, 21600, 25200, 28800, 36000, 43200.
 
(If the tested beat is not in automatically selection, the instrument will display the closest beat number,
 
but the test result is not correct. At this time, use the manual mode to select the relative beat.)
 
Manual selection can selected out the beat number that Automatic select can not identify and rare beat number.
 
The following beat are selected by Manual selection mode:
 
3600,6000, 7200, 7380, 7440, 7800, 9000, 9100, 10800,11880,12000,12342,12480,12600,
 
13320,13440,13500,14000,14040,14160,14200,14280,14400,14520,14580,14760,14850,15000,
 
15360,15600,16200,16320,16800,17196,17258,17280,17786,17897,18000,18049,18514,19332,
 
19440,19800,20160,20222,20944,21000,21031,21306,21600,25200,28800,32400,36000,43200.
 
2.Lift Angle:
 
The lift angle is 52° for many common movements
 
therefore the lift angle value of instrument for factory is set to 52°. This value
 
is required to calculate the amplitude and must be selected according to
 
the watch movement. The lift angle can be set to between 30°and 70°.
 
3.Period:
 
The measuring period selectable 2s、4s、8s、10s、20s、30s、60s
 
Use to recalculate the average values of the test result.
Common Faults & Handling 
 
1. After insert the socket, the screen is dark. Check the power pilot LED is bright or not.
 
2. The instrument can enter testing state with the sound of “Di", but after placed the watch on the sensor,
 
the instrument do not work. Check the second hand whether rotation (and amplitude must be more than 100 °),
 
the crown of watch (leading) is against at the sheet metal of sensor.
 
3. Signal LED is bright, but the lines is scattered or occur many lines. Maybe the beat is mistake,
 
adjusted the right beat (frequency) by manual selection.
 
Package Include

 
1pc Mechanical Watches Tester

(1) Wir liefern in Ihrem eBay oder Paypal-Adresse. Bitte stellen Sie sicher Ihre eBay und Paypal-Adresse korrekt ist, bevor Sie bezahlen.
(2) Artikel werden innerhalb von 1-3 Werktag versendet, sobald wir die Zahlung erhalten.
(3) die Lieferzeit hängt von Ziel und anderen Faktoren ab;
(4) internationale Einkäufer beachten Sie bitte:
a.Import Abgaben, Steuern und Gebühren sind nicht im Artikelpreis oder den Versandkosten enthalten. Diese Gebühren sind Käufer? s Verantwortung. Wir versuchen unser Bestes, um die Gefährdung durch die Zollgebühren.
b.Please erkundigen Sie sich bei Ihrem Land Zollamt, um festzustellen, was diese zusätzlichen Kosten vor dem Kauf.
(5) da wir viele Lagerhäuser haben, vielleicht senden wir die Artikel über verschiedene Pakete aus verschiedenen Lagern Ihnen.Fragen, direkt bitte an Verkäufer CS-Team.
(6) einige Produkte verschifft ausChinesischen lagernWeitere Zahlen zu müssenZollgebühren. Bitte kontaktieren Sie uns, wenn Sie kaufen..

(1) Wir akzeptieren nur PayPal.
(2) alle gängigen Kreditkarten werden durch sicheren Zahlungsprozessor PayPal akzeptiert.
(3) Zahlung muss innerhalb von 14 Werktagen Auktion schließen eingegangen sein.
(4) Wir versenden Ihre eBay oder Paypal-Adresse. Bitte stellen Sie sicher Ihre eBay und Paypal-Adresse ist korrekt vor der Bezahlung.

1. Wenn Sie einen Artikel erhalten, der nicht genau beschrieben ist, kontaktieren Sie uns bitte innerhalb von 45 Tagen nach Erhalt und bevor Sie eine Bewertung abgeben. Nach Erhalt des Originalprodukts, das sich ebenfalls im Originalzustand befinden muss, werden wir eine Rückerstattung ausstellen. Der Käufer ist für die Versandkosten verantwortlich, die beim Rückversand der Produkte anfallen. Wenn wir im Irrtum sind (defektes Produkt oder versendeter falscher Artikel), versenden wir Ihnen gerne einen neuen Artikel.

2. Wir werden unser Bestes tun, um eine Lösung zu Ihrer Zufriedenheit zu erarbeiten!

Copyright©2017 DataCaciques


Am 20.11.20 hat der Verkäufer die folgenden Angaben hinzugefügt:

DataCaciques