Package List:
Depend on the choice you add into your cart.
 
Advantages:
1.Specially design for Difficult root canal cases
 
2.Streamlined handle, easy to operate
3.Has 3 variable from low to high ,it can be adjusted to your preference.
4.Dual Purpose device:
5.2 Popular colors you could chosse welcome to do OEM/ODM to customise the color you want.
6.Battery changed easily.
 
1. Indications For user
 The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm.
The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.
2. Notice
1) Remove the needle tip of EasyDO Activator. If your treatment process is
over, please leave it for medical recycling.
2) Please put exhaustively discharged battery into the recycling box.
3Do not submerge the unit in water.
4Do not autoclave the unit.
 
5Warranty limitations
Content not covered by warranty:
-Needle tip
-Hand device barrier sleeve
-Damage caused by misuse, abuse, neglect of prompt or change of the
equipment usage
-Normal wear and other external scratches, including scratches, wear,
cracks, discoloration or fade.
-Battery replacement
* Note:
If the product is not used for a long time (two weeks or longer), please
remove the battery. It also must be removed during transport, for
example, during delivery
 
10) Properly dispose the Activator needles tip and hand device protective
barriers in accordance with the local laws and regulations and environmental
protection requirements.11) Dispose the battery after being used in accordance with the local laws
and regulations and environmental protection requirements, when battery is
exhausted.
12) The hand device must be repaired if necessary according to the direction
of the manufacturer.
13) Don’t insert needle tip into the hand device. If the equipment is not used
for a long time, placing the hand device into packing box is recommended.
14) Remove the battery when the hand device is not used for a long time.
15) The hand device can be kept at the temperature of 0 ~ 55 ,
relative humidity 0% ~ 75% RH and air pressure750-1060 HPA.
16) The hand device should be keep away from strong electromagnetic
interference, which may affect the performance and normal use of hand
device.
17) The hand device should be kept away from portable or mobile RF
communication devices, which may affect the performance of hand device .
18) The hand device could not be adjacent to or stored with other equipment.
In addition, it is necessary to check regularly whether the hand device can
work normally.
19) Proper disposal of the hand device is required when the hand piece
is deemed no-functional in accordance with local laws and regulations.
 
3. Key points of Operation:
5.1POWER OF BATTERY STATUS
Depress the " ON / OFF Switch" key for 1 second to observe the "Power
Indicator" status around the button of the hand device.
1. If the "Power Indicator" is white, it means the activator system is in
full power status;
2. if the "Power Indicator" is red and white, it means the system is in
half power status;
3. if the "Power Indicator" is red, it means the system is in power
shortage status; 4. If the "Power Indicator" is flashing red, it indicates that the system is
on the verge of power failure.
5. Please note if the "power indicator" is flashing red, please replace the
battery.
 
 