Product features:
1. Use of high quality materials, durable
2. Low voltage alarm, high voltage alarm, over current alarm, low capacity alarm
3. Full screen display of all data, more intuitive
4. Hall inductive non-destructive measurement, wiring super simple
5. Simple and convenient to use
Parameters:
Current measurement range: 50A/100A/200A/400A (self selection)
Supply voltage range: DC5-120V
Voltage measurement voltage: DC0-300V
Voltage resolution: 0.1V
Capacity measurement range: 0~999AH (Note: up to 0~2000AH when only percentage is displayed )
Power measurement range: 0~999KW
Energy measurement range: 0~999KWH
Meter measurement error: + - 1%
Refresh speed: 0.5S refreshing display information
Temperature measurement range: -50 °C~125 °C
Installation slot size: slot size: 76. 0 mm * 40. 5 mm (20 mm in diameter of sensor threading hole)
Operating current: Backlight on: 25MA, backlight off: 9MA (total power 0.3W, different voltage and current)
Function introduction:
1. Measure the remaining battery power percentage % and remaining power AH number.
2. Measure DC positive and negative bi-directional current size. Measure DC voltage size.
3. Measure DC positive and negative power magnitude.
4. Measurement of the accumulated power magnitude in both positive and negative DC directions.
5. Over-voltage alarm function, alarm voltage size parameters can be set by yourself. (With alarm sound and alarm output control CN2)
6. Low voltage alarm function, the alarm voltage size parameter can be set by yourself. (There is an alarm sound and there is an alarm output control CN2)
7. Over-current alarm function, the alarm current size parameter can be set by yourself. (With alarm sound and alarm output control CN2)
8. Low battery remaining alarm function, the power icon will flash continuously, prompting the user to charge. (There is an alarm sound and the alarm output is controlled by CN2)
9. Battery over-temperature alarm function, the size of the alarm temperature can be set by the user. (There is an alarm sound, and there is an alarm output control CN1, which can be used to control the battery cooling fan. Note: All control output signals are weak signals of 10MA, the driving device needs to be amplified by the customer's own external amplifier circuit for control.)
10. Power down data saving function.
11. Using Hall sensor isolated measurement, safe and reliable, wiring installation is very simple and convenient.
Note: Please do not interchange the sensor use!
Package list:
Coulometer*1
Shunt*1
Connection cable*1
Power cord*1