Dental Ultrasonic Surgery Tips Ⅱ Sinus Lift Extraction Satelec ACTEON Piezotome

The second generation tips Ⅱ

Compatible with

-Acteon Satelec Piezotome 2.
-Acteon Satelec Piezotome Solo (LED)
-Acteon Satelec Piezotome Cube.
-Acteon Implantcenter 2.

Essential Kit

Essential Kit

This kit is a selection of the most popular surgical tips kit.
Due to the ultrasonic frequency modulation, a selective cut is achieved in surgical mode. Therefore, these tips limit the risk of soft tissue injury such as gingiva, ligaments, periodontal fibers, and nerves. The sterile spray helps to cool the tips.
These 6 tips can be applied to all of the following interventions:
Osteotomy, osteoplasty (BS1 and BS4 II tips)
Extractions (LC2 II tip)
Sinus Elevation by the lateral approach (SL1 II, SL2 II and SL3 II tips)

Kit including (6 Tips + Tips Holder)

BS1 Ⅱ: Saw intended for cutting of cortical bone in surgical orthodontics, pre-implant surgery,and bone distraction.
BS4 Ⅱ: Circular scalpel angled at 130°, for osteoplasty and harvesting of bone particles or chips. Ridge osteoplasty, periodontal surgery, cysts exerisis, etc.
LC2 Ⅱ: The particularly slim LC2 allows access to the tight spaces between the root and the alveolar bone without risk of damaging cortical bone. Length of active part: 10mm
SL1 Ⅱ: Diamond-coated tip for vestibular bone window cut and for attenuation of sharp angles.
SL2 Ⅱ: Diamond- coated ball tip for smoothing the vestibular bone window and precise osteoplasty. Ball diameter: 1.5mm. Laser mark every 2mm.
SL3 Ⅱ: Plateau-tip, non- cutting, for sinus membrane elevation on the vestibular bone window’s edges. Plateau diameter: 5 mm.

Bone Surgery Kit

Bone Surgery Kit

Thinness and security.
Bone Surgery (BS) tips, principally intended for performing bone graft, allow cutting excising and remodeling bone structures without any risk of soft tissue lesions.
Comprising six ultrasonic tips (three saws and three scalpels) adapted to the different cases that arise in the intraoral environment, the BS Kit is used for dental clinical treatments such as bone harvesting, crest expansion, preparation of the implant site and accessing the lower alveolar nerve.

Kit including (6 Tips + Tips Holder)

BS1 Ⅱ: Saw intended for cutting of cortical bone in surgical orthodontics, pre-implant surgery,and bone distraction.
BS2L Ⅱ: Bone saw with four teeth, used for cutting the ramus cortical bone. Left  oriented, it is used to create vertical and horizontal osteotomy lines on the patient’s right mandible.
BS2R Ⅱ: Bone saw with four teeth, used for cutting the ramus cortical bone. Right  oriented, it is used to create vertical and horizontal osteotomy lines on the patient’s left mandible.
BS4 Ⅱ: Circular scalpel angled at 130°, for osteoplasty and harvesting of bone particles or chips. Ridge osteoplasty, periodontal surgery, cysts exerisis, etc.
BS5 Ⅱ: Flat scalpel, for fine osteotomies. Ridge expansion, thin osteotomy, distraction, preparation of buccal bone flap on thick cortical terrain prior to sinus lift surgery.
BS6 Ⅱ: Curved scalpel particularly effective for substantial osseous reshaping. This tip is used to perform osteoplasties and reshaping of the bone not assuring the tooth support. It can also be used to mark a prosthetic reference point on enamel, if needed, where osteoplasty will begin.

Sinus Lift Kit

Sinus Lift Kit

For unmatched visibility.
The Sinus Lift Kit offers the practitioner a straightforward and safe answer to the lateral sinus lift operation. Thanks to the ultrasonic frequency modulation, the risk of membrane damage is limited. 
The diamond-coated tips for window cutting and the three spatula tips for sinus lift SL1 and SL2 are cooled by the sterile spray (thus avoiding tissue damage from exposure to high temperatures). 
The use of a manual instrument is recommended to control the membrane detachment. Moreover, the cavitation effect enables excellent visibility of the operating field. These tips guarantee a fine, clean and effortless cut.

Kit including (5 Tips + Tips Holder)

SL1 Ⅱ: Diamond-coated tip for vestibular bone window cut and for attenuation of sharp angles.
SL2 Ⅱ: Diamond- coated ball tip for smoothing the vestibular bone window and precise osteoplasty. Ball diameter: 1.5mm. Laser mark every 2mm.
SL3 Ⅱ: Plateau-tip, non- cutting, for sinus membrane elevation on the vestibular bone window’s edges. Plateau diameter: 5 mm.
SL4 Ⅱ: Non-cutting spatula, oriented at 90°, for sinus membrane elevation inside the sinus. Spatula diameter: 4 mm.
SL5 Ⅱ: Non-cutting spatula, oriented at 135°, used for sinus membrane elevation inside the sinus and for disengagement of anatomical structures. Spatula diameter: 4 mm.

Extraction Kit

Extraction Kit

For atraumatic extractions without bone destruction.
This kit is intended for treatment such as extraction of wisdom teeth, fractured roots, impacted teeth and root section. The six ultrasonic tips are each adapted to the anatomical context (reduced visibility and space) of anterior and posterior areas.
Inserted between the cementum and the periodontal ligament of the tooth, the tips will widen the ligamental space. Thus separated from its attachment system, the tooth can be removed rapidly and with a less traumatic luxation. The alveolar bone edge can be kept intact; an alveolectomy is therefore avoided.
Usage guidelines recommendations:
- The tip must be activated before its insertion in the periodontal space.
- The tip must be placed parallel to the root.
- Perform a to-and-fro movement towards the apex.
- It is important not to exert a lever effect with the tips.

Kit including (5 Tips + Tips Holder)

LC1 Ⅱ: To be inserted deeply and with great care, along the periodontal ligament, between the root and the alveolar bone. Length of active part: 9mm
LC2 Ⅱ: The particularly slim LC2 allows access to the tight spaces between the root and the alveolar bone without risk of damaging cortical bone. Length of active part: 10mm
LC2L Ⅱ: Oriented at 45° to the left or to the right, the LC2L/LC2R facilitates access to the posterior areas. The tip’s slimness respects the morphology of cortical bone and offers working comfort in the sectors with reduced visibility. Length of active part: 10mm
LC2R Ⅱ: Oriented at 45° to the left or to the right, the LC2L/LC2R facilitates access to the posterior areas. The tip’s slimness respects the morphology of cortical bone and offers working comfort in the sectors with reduced visibility. Length of active part: 10mm
LC1/90 Ⅱ: To be inserted deeply and with great care, along the periodontal ligament, between the root and the alveolar bone. Length of active part: 9mm.

FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller's name: march-dent
City State: Zhengzhou, Henan China
Telephone number:+86371-61770155

DataCaciques