Genst Controller DC30D for Small Diesel Gasoline Generator Start Stop Monitor

Summary

This Controller Series is specialized for small diesel, gasoline, gas generator sets’start, stop,monitor and defaults checking as well as parameters setting.

The controller has a point array LCD screen, can display various faults in the same time that the genset will be stopped once it can not work smoothly.

There are Chinese/English interface options, more language can be set according to user’s request. All the parameters can be configured through the front face buttons or use programmable interface by USB to adjust via

PC. It can be widely applied for all kinds of auto control system of gensets.


Main Features

32 units Micro-procession technology is used.

1.8 inches 128*64 LCD display with backlight, option language interface (Chinese/English), user’s language set if necessary.

PC front face panel, which is water-proof, oil-proof, UV proof so that the durability is longer.

USB Port: parameters can be set even without power.

All the parameters can be set through front panel buttons.

Collect and display a variety of engine and generator parameters.

Records function: relative faults shall be recorded in real time.

It has 5 relay outputs, 3 of which are configurable, and more than 10 functions can be selected for each channel.

1 switch value input, and each can be set as max 20 functions.

3 sensor simulation input connectors, various kinds of units can be set.

Sensor can be self-defined by front face button or PC software.

Various of crank conditions(RPM,Frequency, Oil Pressure) can be chosen.

Control Protection:Auto Start/Stop of genset,load transfer and perfect failure display and protection.Standard water-proof rubber gasket. The waterproof can reach IP54.

Module design: All the connections are adapted with European connectors so that installation, connection, repair and replacement can be more easily.


Package include:

1 x DC30D Genset controller

1 x User manual in English

2 x Screw


Parameters Display

Engine RPM

Engine oil pressure

Engine temperature

Engine fuel level

Engine battery voltage

Generator voltage L-N

Generator current A

Generator Frequency Hz

Generator active power KW

Successful start Times

Current running time

Total running time

Classes maintenance notice


Protection

Over speed

Under speed

Low oil pressure

High temperature

Low fuel level

External emergency alarm

Sensor Open

Over Frequency

Under Frequency

Over voltage

Under voltage

Over current

Maintenance expire

Low water level alarm

Emergency Stop

Crank failure

Stop Failure

Over battery voltage

Under Battery voltage

Typical Wiring Diagram


Note: Please don’t move battery during running status or it may cause the controller broken!

WARNING: When generator is on-load, C. T. secondary must not be open circuit, Otherwise, the high voltage generated will pose a danger to personal safety.