Main Features:
² Bandwidth: 100MHz
² Measurement channel: 2 analog channels
² Real-time sampling rate:500MS/s
² Storage depth: 64kpts
² Waveform capture rate:5,000wfms/s
² Auto measurement: 34 waveform types
² Abundant trigger: Edge、Pulse width、Slope trigger、Video trigger、Alternating trigger
² Display: 7-inch WVGA(800×480)TFT LCD,super-widescreen, clean display
² Peripheral interface: Standard USB Host, USB Device, EXT Trig, Pass/Fail
² New Autoset function: Customized auto strategy to facilitate oscilloscope teaching
Quick Model Selection
Model | UTD2052CL+ | UTD2102CL+ |
Analog Bandwidth | 50MHz | 100MHz |
Channels | 2 | 2 |
Real-time | 500MS/s | 500MS/s |
Equivalence | 25GS/s | 25GS/s |
Storage depth | 64 kpts | 64 kpts |
Capture rate | 5000 wfms/s | 5000 wfms/s |
Rise Time (Typical) | ≤7ns | ≤3.5ns |
Technical Specification
Horizontal System Specification | |
Time-base scale | 2ns/div-50s/div |
Waveform interpolation | Sin(x)/x |
Time-base accuracy | ≤(50+2×Service life)ppm |
Record length | 2×512k sampling point |
Storage depth | Single channel: 64k;Double channel: 32k |
Sampling rate and delay time accuracy | ±50ppm (any time interval ≥1ms ) |
Measurement accuracy of time interval (△T) (full bandwidth) | Single time: ± (1 sampling time interval+50ppm×reading+0.6ns) |
Vertical | |
Analog-to-digital converter (A/D) | 8bit |
Deflection factor range (V/div) | 1mV/div~20 V/div (at 1-2-5 increment) |
Position range | ≥±8div |
Selectable bandwidth limitation (Typical) | 20MHz |
Low frequency response (AC Coupling,-3dB) | ≤5 Hz(above BNC) |
DC gain accuracy (sampling or average sampling mode) | 5mV ~20V/div:≤±3% |
DC measurement accuracy (average sampling mode) | When vertical position is 0 and N≥16: |
Measurement accuracy of voltage difference (△V) (average sampling mode) | Under the same setting and environment conditions and after averaging the captured waveforms with a quantity of ≥16, the voltage difference (ΔV) between any two points on the waveform: ± (3%×reading+0.05div) |
Trigger System Specifications | |
Trigger sensitivity | ≤1div |
Range of trigger level | Interior:From the screen center ±10div |
Trigger level accuracy (Typical) applicable for the signal with rising and falling time ≥20ns | Interior:±(0.3div×V/div) (within±4 div from the screen center) |
Pre-trigger capacity | Normal mode/scan mode, pre-trigger/delay trigger, the pre-trigger depth is adjustable. |
Hold-off range | 80ns~1.5s |
Set the level to 50% (Typical) | Operate under the condition of input signal frequency of ≥50Hz |
Trigger mode | AUTO, normal, single |
High-frequency holdoff | Hold off signals over 80kHz |
Low-frequency holdoff | Hold off signals below 80kHz |
Trigger mode | |
Edge | Rise, fall, arbitrary edge |
Pulse width | Pulse width term:>、<、= |
Polarity:positive pulse width, negative pulse width | |
Pulse width range:20ns~10s | |
Slope trigger | Slope condition:Positive slope (>, <, within the scope);Negative slope (>, <, within the scope) |
Time:20ns~10s | |
Video trigger | Trigger sensitivity (Typical) :2div Vpp |
Signal model and line/field frequency (video trigger type): | |
Alternating trigger | Alter:Edge, Pulse, Slope |
Measurements | |
Cursor | Manual mode |
Track mode:Voltage value and time value of point of waveform. | |
Auto measurement mode:Cursor display is allowed on auto measurement mode. | |
Automatic measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vmid, Average, Vrms, Overshoot, Preshoot, Frequency, Period, |
Measurement quantity | Display 5 types of measurement at the same time. |
Measurement scope | Screen or cursor |
Measurement statistics | Average value, maximum value, minimum value and standard deviation. |
Math | |
Math operation | +,-, ×, ÷ |
Window | Rectangle、 Hanning 、Blackman 、 Hamming |
Vertical scale | Vrms、 dBVrms |
Digital filtering | Low pass, high pass, band pass, band reject |
Storage | |
Setting | Internal: 20 groups. USB: 200 groups |
Reference waveform | Internal: 20 groups. USB: 200 groups |
Data file | Internal: 20 groups. USB: 200 groups |
Bitmap | USB: 200 groups, in BMP format. |
Input Channel Specifications | |
Input Coupling | DC, AC and GND |
Input impedance | (1MΩ± 2%)//(18pF± 3 pF) |
Probe attenuation coefficient | 0.01×/0.02×/0.05×/0.1×/0.2×/0.5×/1×/2×/5×/10×/20×/50×/100×/200×/500×/1000× |
Maximum input voltage | 400Vpk, the transient over voltage is 1000 Vpk. |
Display | |
Displays types | LCD with Diagonal of 178mm (7-inch) |
Display resolution | 800 horizontal×RGB× 480 vertical pixels |
Display color | Color |
Waveform luminance | Adjustable |
Backlight intensity (Typical) | 300nit |
Language | Multi-language |
Interface function | |
Standard configuration | Standard USB Host, USB Devic e, EXT Trig, Pass/Fail |
Trigger frequency meter | |
Reading resolution | 6bits |
Trigger sensitivity | ≤30Vrms |
Accuracy (Typical) | ±51ppm (+1 character) |
Probe compensator output | |
Output voltage (Typical) | About 3Vpp, when the load≥1MΩ |
Frequency (Typical) | 10Hz,100Hz,1kHz (Default), 10kHz |
Power Source | |
Power voltage | 100V-240V~(Fluctuations 10% ) ,50/60Hz |
Power consumption | 100VA max |
Fuse | F 1.6A 250V |
Environment Specifications | |
Intended use | Indoor use |
Pollution degree | 2 |
Operating temperature | Operating Temperature Range: 0℃~+40℃ |
Storage Temperature | Storage Temperature Range: -20℃~+60℃ |
Cooling | Build-in cooling fan |
Operating Humidity Range | <35℃: ≤90%RH |
Operating Altitude | Operating 2000 meters below |
Mechanical specifications | |
Size | 306mm(W) ×138(H)×124 mm(D) |
Weight | Excluding package:2.5kg Including package: 3kg |
Recommended calibration Interval | |
The recommended calibration interval is one year. |