For Refrigeration Freezer Dixell XR06CX-4N1F1 Temperature Thermostat Controller
XR06CX-4N1F1
For Refrigeration Freezer Dixell XR06CX-4N1F1 Temperature Thermostat Controller

Description:
High quality follow the original factory specifications & Most products are brand new(Except remanufactured products)
Free Fast Shipping from US warehouse
Any question contant us though eBay message.
Please make sure the OEM number in our listing is the same as your original one.
(Note: Weekend message will be replied on the next working day)

The XR06CX, format 32x74x60 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with 2 NTC probe inputs, the first one for temperature control, the second one, to be located onto the evaporator, to control the defrost termination temperature and to managed the fan and it's provided with a configurable digital input. With the HOTKEY it's possible to program the instrument in a quick and easy way.
 
Suitable for appliances including
for applications on medium or low temperature ventilated refrigerating units

Replace Part Number: 
XR06CX-4N1F1 XR06CX4N1FI XR06CX 4N1FI
Professional Installation Is Highly Recommended.

Specification
Type: XR06CX-4N1F1
Mounting Measurements: 71mm x 29mm
Built-in Depth: 56mm
Supply: 110V
Voltage Type: AC
Probe Type: NTC (probes not included)
Number of Relay Outputs: 1
Relay Output 1: NO-20A(8)
Input: 1NTC
Kind of Protection: IP54
Version: Defrosting Function / Time Control
Measuring Range: -40°C up to +110°C
Display: 2½ Digit

With FC parameter it can be selected the fans functioning
• FC=cn will switch ON and OFF with the compressor and not run during defrost
• FC=on fans will run even if the compressor is off, and not run during defrost
After defrost, there is a timed fan delay allowing for drip time, set by means of the Fd
parameter.
• FC=cy fans will switch ON and OFF with the compressor and run during defrost
• FC=oY fans will run continuously also during defrost.
An additional parameter FS provides the setting of temperature, detected by the evaporator
probe, above which the fans are always OFF. This is used to make sure circulation of air only if
his temperature is lower than set in FS.

FANS AND DIGITAL INPUT
When the digital input is configured as door switch iF=do, fans and compressor status
depends on the dC parameter value:
dC=no normal regulation;
dC=Fn fans OFF;
dC=cP compressor OFF;
dC=Fc compressor and fans OFF.
When rd=y, the regulation restart with door open alarm

SAFETY PRECAUTIONS
• Check the supply voltage is correct before connecting the instrument.
• Do not expose to water or moisture: use the controller only within the operating limits avoiding
sudden temperature changes with high atmospheric humidity to prevent formation of
condensation.
• Warning: disconnect all electrical connections before any kind of maintenance.
• Fit the probe where it is not accessible by the End User. The instrument must not be opened.
• In case of failure or faulty operation send the instrument back to the distributor 
• Ensure that the wires for probes, loads and the power supply are separated and far enough
from each other, without crossing or intertwining.
• In case of applications in industrial environments, the use of mains filters (our mod. FT1) in
parallel with inductive loads could be useful.

Package included:
1 X Digital Thermostat Controller(as pictures show)

PLease Note:
---Communication is the best way to solve the problem.
---If you have any problems after purchasing, please contact us in time, before opening return or case
---Please be very careful to check our photos, make sure the photos showed is the same as you wanted.

We currently accept Paypal
bestsellingseller2020 locates in CA, all items ship from California.
It usually takes 3-7 business days to arrive depends on the shipping method.
If buyer ordered the wrong part or wouldn't want it anymore, we would charge 15% restocking fee.
Feedback from our valued customers are highly appreciated!
If there is any problem with our product or servie, please contact us through ebay message before leaving any negative feedback!
We promise we will solve every issue you ever encounter anytime!
bestsellingseller2020 is a professional retailer and manufacturer on automotive parts!
Please contact us through ebay message.
We will get back to you within 8 hours from Monday to Sunday!
PushAuction