TESTS CONDITIONS (datasheet)

DUOVAC RADIOELEC 
Va=90V Vg=-1,3V Ia=15mA 

HICKOK TV7D/U 
EV2-1030 B21 D min=50 (100%=83)
EV7-6080 B21 D min=50 (100%=83)

Please note that HICKOK is not a laboratory tester, though it is very well calibrated...
HERE is how I calibrated mine following manual services specifications. I calibrated it to respect the low of the scale for filament... High voltage on filament would damage it...but gives higher values...
0.6 (065-0.72)   -->0.65V ; 1.1 (1.06-1.16)  -->1.14V ; 1.5 (1.26-1.42)  -->1.30V ; 2.0 (1.90-2.10)  -->1.95V ; 2.5 (2.56-2.88)  -->2.77V ; 3.0 (3.25-3.60)  -->3.25V ; 4.3 (4.30-4.75)  -->4.55V ; 5.0 (5.15-5.68)  -->5.49V ; 6.3 (6.20-6.80)  -->6.47V ; 7.5 (7.32-8.10)  -->7.45V ; 10 (9.60-10.80) -->10.03V ; 12.6 (12.1-13.3) -->12.25V ; 20  (19.0-21.0)   -->20.50V ; 25  (25.3-28.0)   -->27.65V ; 35  (35.2-39.0)   -->38.09V ; 50  (51.5-57.0)   -->52.80V ; 75  (74.0-82.0)   -->74.82V ; 117 (115-127)    -->116.5V
If needed, i can share all other tests calibrations I get (129.5V/130V +o-3V ; 41.35V/40V +o-2V ; 4.21V/4V +o-1V ; 56.5V /56V....) 

 

7L8 SB
RING GETTER F4H5 code 12,2mA/11,3mA 62/54 


ASK FOR OTHER REFERENCES IF NEEDED. THE ENTIRE STOCK IS NOT ONLINE. I COMBINE SHIPPING.


EUROPE COUNTRIES, YOU CAN ASK FOR MONDIAL RELAY DELIVERY SERVICE. IT'S LESS EXPENSIVE THAN LAPOSTE, ASK BEFORE PAYING IF YOU CHOOSE THIS SERVICE.


TUBES ARE GLASS MADE, THEY ARE FRAGILE. IF YOU SELECT A SIMPLE "BUBBLE LETTER" FOR THE DELIVERY, I WON'T BE RESPONSIBLE IF THEY ARE BROKEN... YOU ASSUME ENTIRE CUSTOMS FEES.