NH3 Ammonia Gas Detector With Sound And Light Alarms For The Chemical Industry ZY500D
Functional features:
The ZY500D series gas detector is based on advanced microprocessor technology and designed specifically for customer needs. The latest mechanical and electronic technologies provide reliable designs for various gas detection requirements, effectively resisting electromagnetic interference and harsh external environmental influences. Advanced imported sensor technology can monitor combustible gases, toxic gases, and oxygen deficiency hazards; The ZY500D series gas detector has two shell options: stainless steel and die cast aluminum, which can continuously monitor combustible and toxic gases. The instrument comes with a digital tube display, which can directly view the on-site gas concentration through the screen. There is no need to open the cover on site, and alarm point settings, coefficient modification, and other operations can be carried out through the remote control. It has two built-in onboard relays, which can be externally connected to sound and light alarms or control functions such as on-site fans and exhaust fans.
By using transmission methods such as 3-4 core cables to connect to environmental protection systems, enterprise servers, central control alarms, user mobile phones, etc., combined with data analysis software, remote monitoring, remote control, and remote alarm can be achieved. Users can perform real-time data queries, historical data queries, data exports, data printing, and other operations on various networked terminal devices through the network.
Features:
1. Multiple wiring methods: Supports RS485 (Modbus communication protocol) and 4-20mA communication methods, with stronger compatibility;
2. Stainless steel material: 50MM diameter air chamber, which prevents the sensor from being affected by external environment and can cope with various harsh environments; Possible corrosive environments
Choose stainless steel casing;
3. Rationality: The detector adopts a design without a back cover, eliminating the problem of detector water intrusion;
4. Intelligent protection: The detector has automatic recognition and protection functions for sensor short circuit and open circuit faults;
5. Support various sensors: By connecting different sensor components, it is possible to detect different gas objects;
6. EMC: Stable and reliable circuit design ensures good stability and strong anti-interference ability of the detector;
7. LED display screen: Using LED digital tube display screen, it has the best visibility even in low light places;
8. Non open cover calibration: Infrared remote control design, on-site calibration of the detector can be completed without opening the cover;
※
Gas | NH3 Ammonia Gas Detector | Ex | Ex d ⅡCT6 Gb |
Range | 0-100ppm | Principle | Catalytic combustion |
Resolution | 0.1ppm | Protection level | IP66 |
Protection level | Aluminum alloy with black coating | Protection level | 4-digit high brightness LED display |
Accuracy | ≤±3 %F.S | Pipeline interface | M40*1.5 |
Duplicate value | ≤1%F.S | Electrical interface | 3/4 "NPT internal thread, 1/2" NPT internal thread, supporting two electrical connection methods simultaneously |
Response Time | T90≤20S | response time | ≤10S |
Relay | Passive contact, capacity,220VAC 3A/24VDC 3A | Zero drift | ≤±1%(F.S/Y) |
Main material | Aluminium Alloy | Main material | Diffusion type, flow type, and pump suction type are optional |
Out | 4-20mA signal RS485 signal adopts standard MODBUS RTU protocol | Size | 200mm×150mm×100mm |
Working temperature | -40~70℃ | Installation method | Wall mounted, flange type, pipeline type |
Working humidity | 0~95%RHNon condensation | weight | 1.5KG |
Power | 9-30VDC,Rated 24VDC | Standard accessories | Manual, infrared remote control |
Working pressure | 86-108Kpa | Optional explosion | Proof sound and light alarm, installation bracket, etc |