9.99A 30V 60W Constant Current Electronic Load Discharge Battery Capacity Tester
110W 30V Constant Current Electronic Load Discharge Battery Capacity Tester 0.10-9.99A 0.9-28.0V

brand new and
Electrical components
Color: See pictures

New Upgrade:
1. The test current is changed from 0.20-9.99A to 0.10-9.99A.
2. The lower limit and termination is changed from 1.0-25.0V to 0.9-28.0V.
3. Support non-operational display.
4. Increase the support for four-wire test in electronic load with independent four-wire
5. The LED indication setting digit is changed to the current setting digit flashing indication.

Features:
Cause sterility new New , simple and versatile electronic load ! Automatic memory function with all parameters , is well suited for automated assembly of the power adapter aging cabinet In the sale of the latest version , slightly larger size and upgrade the fan into 5020 for high speed bearing fan , cooling redundancy , more suitable for long hours
Note: This product is a professional testing equipment , requiring the user must have some basic electronic ( example: Users should understand what is the meaning of the and current capacity Ah , ) , or you may be unable to properly use the device , possibly mishandled cause unnecessary damage caused by the test device loss ! PPower supply requirement : DC12V ( actual 11-14V) current is not less than 0.5A of power, the power will be displayed inappropriate Err6
Note: The default power adapter is not included

Specifications:
Operating modes: single constant current
Discharge current : 0.10-9.99A stepper 0.1A or0.01A
Discharge current error : 0.7% -0.01A
The capacity test error : 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
Offline ( termination ) : 0.9-28.0V. stepping 1V or 0.1V
Discharge : 1.00-30.00V
The measurement error : 1% + 0.02V
it can open 9.99A 6V and 20V at the only open 3.00A)
Highest test statistic : 999.9Ah or 9999Wh, achieve value stop testing ( first value to those who stop condition
Board size : 60W 100mm * 70mm * 57mm ( fan prominent board about 12mm)
Positioning hole locations : 60mm * 88mm diameter 3.2mm 5mm pedestal already installed
Fan control : intelligent fan control ( according to the radiator fan can be infinitely variable automatic temperature
Protection: Overheat for protection "otP", transient overpower for protection overpressure for protection "ouP", reverse polarity for protection, power supply abnormal for protection
Instructions::
A : settings ( default factory for electronic load ) : Hold down the start-stop button ( red button ) to the tester simultaneously energized until the for key is released showing Fun * When , by rotating the knob to change the setting , "Fun1" for electronic load , "Fun2" capacity test Push button and stop at the buzzer after entering the settings, also set "bEon" buzzer by turning the knob to open or "bEoF" buzzer closes After setting press the button again to and stop at the tester
Setting Digital
II: Electronic Load
1. Turn on the power supply 12V boot into electronic load , ensuring in a stopped ("RUN" does not light, otherwise the press of the start-stop to turn off the load ) to the power supply under test to the test port input power + ) , pay attention not to take the wrong polarity
2. Set current and lower knob , turn the knob to set the value of the current setting position , then press the
knob to change the setting digit, digital middle two digits to the right of the and digital VA simultaneously
determine the current set position
3. Press the start-stop , load began to run , "RUN" lights , power is applied to the circuit under test is set to enter the
discharge current , while the upper display the actual input load , when the drops the set limit " RUN " LED flashes and short beep alarm buzzer accompanied.
4. The test procedure can be modified at any current , and if you need to modify the lower to stop the load can modify
Note:When in alarm , can only transfer a small current does not increase !Tester automatic power-down feature to save enough to save the set parameters and run when the again after power transmission will before the power failure and data.
3: The capacity test
1. The test should be fully charged with a special
2. Give the tester is powered into the capacity test the current line to + positive and negative terminals , if you use four-wire clamp test, while the four-wire to the positive and negative test fixture is to + port.
3. Turn the knob to set the discharge current and discharge ( referring to two specific methods : 2 Description ) , press after setting the and stop , a tester and a first line detection, automatic identification 2-4 line ( 2-wire line identification presentation JS-2,4 identification
4, if an error please stop the test and check the wiring ) , then enter the test , if the fault code appears , refer to later explain
The testing process will round up digital noticeable , current , and the current discharge capacity Ah discharge energy Wh, when the discharge end ( is the set ) , the tester displays the data stays in Ah and b-link rapidly , with shortness buzzer alarm.
5. Press the and stop at the knob or to stop the alarm , you can turn the knob to view the discharge data , including discharge capacity
Ah, Wh and discharge energy platform start-stop button is pressed again , clear the data back to the initial setting before testing the next section batteries.
Additional information:
1. Battery test process can adjust the discharge current , if you need to re- adjust the termination , you can by pressing the at the and stop the discharge modification ( discharge will return to the settings page , this for time discharge data is not lost , if necessary , you can long
press clears the data until the start-stop 0.000Ah).
2. Tester automatic storage can record setting parameters , and record all parameters and at the end of the test process and test power failure alarm , re- transmission of all automatically restored.
Fault for protection codes and meanings
Err1: ultra-high capacity test the
Err2: is the set termination is not to the or the is reversed
Err3: line resistance is too large or the can not afford to set the discharge current.
Err4: circuit failure
Err6: working power is inappropriate , use a standard 12V power supply , and the supply current is not less than 0.5A. otP: overheating for protection.
Ert: temperature failure or the temperature is too low.
ouP: ultra-high electron -load
under ultra-high power electronic load instantly
No retail package
Quantity:1Pc
Note: Due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!!

Package included:
1 * Electronic Load Battery Capacity Tester